Thermo Scientific™ Nalgene™ System 100™ Kryogene hætteglas

Artikelnummer. 13417659 Shop alle Thermo Scientific produkter
Skift visning
Klik for at se tilgængelige muligheder
Volumen (metrisk):
1 ml
1,5 ml
Pakningsstørrelse:
Pakke med 500
2 product options available for selection
Product selection table with 2 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Volumen (metrisk) unitSize
13417659 1 ml Pakke med 500
12784716 1,5 ml Pakke med 500
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 2 options available.
2 options
Denne vare kan ikke returneres. Se returpolicy

Cryogenic vials are intended for placement only in the vapor phase of liquid nitrogen, and should not be used for storage in the liquid phase of liquid nitrogen. Immersion of the vials in the liquid phase could result in penetration of the liquefied gas into the vial, resulting in rapid vaporization of the liquid upon removal and possible violent explosion or leakage from the vial/closure perimeter.

To prevent cryogenic vials from exploding, never overfill liquid nitrogen storage units. Always examine vials before use to ensure no visible defects around the closure rims. Always use full faceshields, heavy safety gloves and laboratory protective apparel when removing vials from cryogenic storage. Always permit vials to warm slowly in a biological safety cabinet. Never reuse cryogenic vials.

Artikelnummer. 13417659 Leverandør Thermo Scientific™ Leverandørnr. AY509X32
Kun null tilbage
Læg i indkøbskurv
Læg i indkøbskurv
Denne vare kan ikke returneres. Se returpolicy

Cryogenic vials are intended for placement only in the vapor phase of liquid nitrogen, and should not be used for storage in the liquid phase of liquid nitrogen. Immersion of the vials in the liquid phase could result in penetration of the liquefied gas into the vial, resulting in rapid vaporization of the liquid upon removal and possible violent explosion or leakage from the vial/closure perimeter.

To prevent cryogenic vials from exploding, never overfill liquid nitrogen storage units. Always examine vials before use to ensure no visible defects around the closure rims. Always use full faceshields, heavy safety gloves and laboratory protective apparel when removing vials from cryogenic storage. Always permit vials to warm slowly in a biological safety cabinet. Never reuse cryogenic vials.

Selvstående hætteglas med udvendigt gevind af polypropylen

  • Steril
  • Til brug med System 100 CryoBoxes™ og 25- og 81-ampulkasser med 2,0 ml ampulkapacitet

TRUSTED_SUSTAINABILITY

Tekniske data

Materiale Polypropylen
Sterilitet Steril
Volumen (metrisk) 1 ml
Trådstil Udseende
Mængde 500/Cs.