Perform susceptibility testing of Streptococcus species with this FDA cleared, convenient plate including Tigecycline.

Perform susceptibility testing of Streptococcus species with Thermo Scientific™ Sensititre™ Streptococcus STP6F AST Plate. This plate is FDA-cleared for automated or manual reading of Streptococcus species using the Thermo Scientific™ Sensititre™ ARIS™ 2X ID/AST System, Thermo Scientific™ Sensititre™ OptiRead System, or Sensititre™ manual platforms, including the Thermo Scientific™ Sensititre™ Vizion™ System for maximum versatility.

Eliminate offline tests with a full range of antimicrobials, including Tigecycline, with the Sensititre Streptococcus STP6F AST Plate. 

  • Individual packaging allows laboratories to test one isolate at a time
  • Test 20 antimicrobials on a single AST plate for cost-effective results
  • True MIC results provide better resistance tracking
  • Extended shelf life and room-temperature storage eliminate inventory control concerns

Not all products are available for sale in all territories. Please inquire.

VersaTREK™ and Sensititre™ products are now part of the Thermo Scientific brand.

TRUSTED_SUSTAINABILITY

Tekniske data

0,5 McFarland Standard MHB (Part No. T346205)
Antimikrobielle midler Various
Bouillon type MHB w/ LHB (Part No. CP114)
Oversigt Sensititre Streptococcus species MIC Plate
Antibiotikum kode Various
Produkttype AST Plate
Test Type Minimum Inhibitory Concentration (MIC)
Til brug med (applikation) All Streptococcus sp.
Inkubationsbetingelser 34-36°C O2
Inkubationstid 20-24 hr
Isolerer pr. plade 1
nr. pr. pakke 10
Emballagetype Box
Mængde 10 stk./pakke
Læsemuligheder Autoread or manual
Overførselsvolumen 100µL
Volumen pr. brønd 100 μL
Arter Streptococcus species
Vis mere Vis mindre