Thermo Scientific™ PepMap™ 300 C4 HPLC Columns

Artikelnummer. 11352213 Shop alle Thermo Scientific produkter
Klik for at se tilgængelige muligheder
Længde (metrisk):
5 mm
150 mm
Diameter (metrisk):
0.075 mm
0.3 mm
1 mm
Emballagemateriale:
Silica
Spherical, Fully Porous, Ultrapure Silica
Pakningsstørrelse:
Hver
Pakke med 5
Denne vare kan ikke returneres. Se returpolicy

Artikelnummer. 11352213

Brand: Thermo Scientific™ 163579

Denne vare kan ikke returneres. Se returpolicy

Use this nanocolumn, packed with 300Å wide pore silica for high-resolution analyses of hydrophobic proteins and peptides.

Separate hydrophobic peptides and proteins, providing higher recoveries with Thermo Scientific™ Acclaim™ PepMap™ 300 C4 LC Columns.

  • High resolution in protein identification, biomarker discovery and systems biology
  • Particular loadability allows hghest sensitivity in LC/MS
  • Designed for TFA-free LC-MS, minimizing ion-suppression effects
  • Optimized for coupling to ESI/MS and MALDI-MS
  • Highest column-to-column reproducibility
  • Easy-to-use, cutting-edge miniaturized HPLC
TRUSTED_SUSTAINABILITY

Tekniske data

Kolonneformat Analytical Column
Diameter (metrisk) 0.075 mm
Flowhastighed 200 nL/min
Til brug med LC/MS, ESI-MS, MALDI-MS
Længde (metrisk) 150 mm
Maks. Tryk 7250 psi (500 bar)
Partikelstørrelse 5 μm
pH 2 to 8
Porestørrelse 300 Å
Overfladeareal 450 m²/g
Temperatur 60°C
USP type L26
Stationær fase C4
Produktlinje nanoLC
Emballagemateriale Spherical, Fully Porous, Ultrapure Silica
Kulstofbelastning 3%
Kolonnetype Reversed Phase
Endcapped Yes
Fase Reversed Phase
Type Analytical Column
Vis mere Vis mindre

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Korrektion af produktindhold

Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

Produkttitel

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.

Mange tak! Din feedback er blevet sendt. Hos Fisher Scientific arbejder vi altid på at forbedre vores indhold for dig. Vi sætter pris på din feedback.