missing translation for 'onlineSavingsMsg'
Få mere at vide

Epredia™ MultiVision Polymer Detection System

Artikelnummer. 12683987 Shop alle Epredia produkter
Klik for at se tilgængelige muligheder
Mængde:
12 mL
Pakningsstørrelse:
12ml
Denne vare kan ikke returneres. Se returpolicy

Artikelnummer. 12683987

Brand: Epredia™ TL012MARH

Venligst for at købe denne vare. Brug for en webkonto? Register dig hos os i dag!

Denne vare kan ikke returneres. Se returpolicy

Employ a simple and robust one-step polymer detection system for visualization of two antigens simultaneously in blue and red with the Epredia™ Lab Vision™ MultiVision Polymer Detection System.

MultiVision AP and HRP polymers are innovative, patented technologies consisting of smaller amino acid polymer subunits that minimize conflicts in binding the target protein. The smaller polymer allows for decreased binding conflicts resulting in more consistent staining and better signal amplification.
  • A primary antibody cocktail of choice may be used in conjunction with ready-to-use MultiVision polymer cocktail, composed of anti-Mouse/alkaline phosphatase (AP) and anti-Rabbit/horseradish peroxidase (HRP)
  • Cocktail is specially formulated from MultiVision polymers that provide increased sensitivity, time-savings, and detection simplicity
  • Yields higher sensitivity and antibody efficiency as well as better signal-to-noise ratios
  • Biotin-free, eliminating background staining
  • Antigen Specificity: anti-Mouse IgG (H+L) and anti-Rabbit IgG (H+L)

  • Enzyme: Peroxidase and Phosphatase

  • Chromogen/Substrate: LVBlue/ LVRed

Includes:

TL-012-MARH: 1 MultiVision anti-rabbit/HRP + anti-mouse/AP polymer (cocktail) (TL-012-MAM), 1 Ultra V block (TA-012-UB), 1 Hydrogen Peroxidase Block (TA-012-HP), 1 LVBlue AP Buffer (TA-075-TMM), 1 LVBlue Chromogen Vial 1 (TA-001-AB1), 1 LVBlue Chromogen Vial 2 (TA-001-AB2), 1 LVBlue Chromogen Vial 3 (TA-001-AB3), 1 LVRed Chromogen Vial 1 (TA-004-HR1), 1 LVRed Chromogen Vial 2 (TA-002-HR2), 1 LVRed Chromogen Vial 3 (TA-002-HR3), 1 LVRed Chromogen Vial 4 (TA-002-HR4), 1 Mounting Media (TA-005-UA)

Note:

MultiVision Polymer Detection System may be employed with any primary antibody cocktail to visualize the presence of two proteins simultaneously. After the specific antibodies are bound to their respective antigens in tissue sections, the rabbit and mouse primary antibodies are located by a specially formulated cocktail of secondary antibody polymers: MultiVision anti-rabbit/HRP + MultiVision anti-mouse/AP. In general, the amino acid polymer is conjugated to AP or HRP enzymes and the Fab fragments of goat anti-rabbit or goat anti-mouse immunoglobulins. The polymer complex is then visualized with first the LVBlue chromogen for AP activity and after washing with the LVRed chromogen for HRP activity. A weak hematoxilin nuclear counterstain is not recommended.

TRUSTED_SUSTAINABILITY

Tekniske data

Chromagen LVBlue
Enzym Peroxidase, Phosphatase
Produktlinje Lab Vision™
Specificitet anti-Mouse IgG (H+L), anti-Rabbit IgG (H+L)
Substrater LVRed
Inkluderer TL-012-MARH: 1 MultiVision anti-rabbit/HRP + anti-mouse/AP polymer (cocktail) (TL-012-MAM), 1 Ultra V block (TA-012-UB), 1 Hydrogen Peroxidase Block (TA-012-HP), 1 LVBlue AP Buffer (TA-075-TMM), 1 LVBlue Chromogen Vial 1 (TA-001-AB1), 1 LVBlue Chromogen Vial 2 (TA-001-AB2), 1 LVBlue Chromogen Vial 3 (TA-001-AB3), 1 LVRed Chromogen Vial 1 (TA-004-HR1), 1 LVRed Chromogen Vial 2 (TA-002-HR2), 1 LVRed Chromogen Vial 3 (TA-002-HR3), 1 LVRed Chromogen Vial 4 (TA-002-HR4), 1 Mounting Media (TA-005-UA)
Mængde 12 mL
Korrektion af produktindhold

Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

Produkttitel

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.

Mange tak! Din feedback er blevet sendt. Hos Fisher Scientific arbejder vi altid på at forbedre vores indhold for dig. Vi sætter pris på din feedback.