KDalert™ GAPDH Assay Kit

The Ambion™ KDalert™ GAPDH Assay Kit is for the reliable measure of GAPDH enzyme activity in cultured human, mouse, or rat cells in less than 30 minutes using a microplate fluorometer. The kit includes sufficient reagents for 375 reactions.

  • Assess GAPDH siRNA delivery in 1/3 the time for 1/3 the cost of real-time PCR
  • Analyze 1-96 samples simultaneously
  • Measure both GAPDH siRNA-induced knockdown AND transfection-induced toxicity
  • Compatible with a wide variety of cells and a broad range of culture conditions

    The KDalert GAPDH Assay Kit is an ideal positive control for transfection optimization experiments and also measures transfection induced cytoxicity. It is designed for use with Ambion™ Silencer™ GAPDH siRNA.

    Rapid, Time-Saving Procedure
    Use the assay to optimize siRNA transfection by transfecting individual cell samples with a GAPDH siRNA and a negative control siRNA. Two to three days after transfection, simply add the included cell lysis buffer to the cells, incubate for 20 minutes, add the diluted master mix of assay reagents, and read the increase in fluorescence four minutes later using a microplate or standard fluorometer. The assay procedure can be completed in about 30 minutes with minimal sample handling.

    One Assay for Two Readouts
    Because GAPDH is expressed at relatively constant levels, the assay can also be used to monitor transfection agent induced toxicity. For this analysis, GAPDH enzyme activity from negative control siRNA-transfected cells is compared to that of untreated cells. Reduced GAPDH activity in negative control-transfected cells compared to non-transfected cells is an indication that the transfection-induced cytotoxicity.

    Accessory Products:
    The KDalert™ Kit is designed for use with Silencer™ GAPDH siRNAs (SKUs #AM4605, AM4633, AM4634, AM4624, AM4632, or AM4631). Additional KDalert™ Lysis Buffer (SKU #AM8790G) is also available separately.
  • TRUSTED_SUSTAINABILITY

    Tekniske data

    Indhold og opbevaring KDalert Lysis Buffer can be stored at –20°C or 4°C. Solution A, Solution B, and Solution C should be stored at –20°C. GAPDH Enzyme should be stored at or below –70°C.
    Assay GAPDH Assay
    Detektionsmetode Fluorescence
    Produktlinje Ambion™, KDalert™
    Produkttype GAPDH Assay Kit
    Substrategenskaber Chemical Substrate
    Tilstrækkelig til 375 Reactions
    Til brug med (applikation) Absorbance, Fluorescence Intensity
    Mængde 375 Reactions
    Forsendelsestilstand Dry Ice
    Mål GAPDH
    Vis mere Vis mindre

    For Research Use Only. Not for use in diagnostic procedures.

    Korrektion af produktindhold

    Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

    Produkttitel

    Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.