missing translation for 'onlineSavingsMsg'
Få mere at vide

Invitrogen™ Human IL-8 ELISA Kits

Artikelnummer. p-4531774
Klik for at se tilgængelige muligheder
Mængde:
1 pladesæt
5-plades sæt
Tilstrækkelig til:
5 x 96 mikropladebrønde
96 mikropladebrønde
Prøvetype:
Cellekultursupernatant, plasma (EDTA, citrat, heparin), serum, Plasma (EDTA, Citrate, Heparin), Serum
Cellekultursupernatant, plasma (EDTA, citrat, heparin), serum, urin, Plasma (EDTA, Citrate, Heparin), Serum, Urine
Cellekultursupernatant, plasma (EDTA, citrat, heparin), urin, Plasma (EDTA, Citrate, Heparin), Urine
Pakningsstørrelse:
1 sæt
Denne vare kan ikke returneres. Se returpolicy

Artikelnummer. 10167393

Brand: Invitrogen™ EH2IL8

Venligst for at købe denne vare. Brug for en webkonto? Register dig hos os i dag!

Denne vare kan ikke returneres. Se returpolicy

Interleukin 8 Recombinant protein SIL8 from Thermo Scientific™ specifically detects Interleukin 8 in Not Applicable samples, and it is validated for Control, ELISA and WB

Assay IL-8 (human interleukin-8) levels in human serum, plasma (EDTA, heparin, sodium citrate), urine and culture supernatant samples with our Invitrgen™ Human IL-8 ELISA Kits.

These human IL-8 ELISA kits use pre-titered, matched pairs of coating and detection antibodies to achieve sensitive and accurate measurement of interleukin-8 (IL-8) in samples at 50 to 100μL per well. Also included are calibrated recombinant protein standard, streptavidin-HRP, TMB substrate solution and stop solution. The complete kits contain precoated 96-well strip plate(s) and lot-optimized reagents. The economically-priced reagent kit provides validated reagents only, requiring users to coat their own plates. The antibody-pair kit consists of the matched IL-8 antibody pairs and IL-8 standard only. All components undergo quality control testing to minimize lot-to-lot variability.
  • Target: Natural and recombinant human interleukin-8 (IL-8) and has been shown to recognize IL-8 derived from stimulated human umbilical vein endothelial cells

  • Format: Colorimetric ELISA (TMB substrate) in clear 96-well strip plate

  • Measurement: Absorbance at 450nm minus absorbance at 550nm

  • Assay Range: 25.6 to 1000pg/mL

  • Sensitivity: < 2pg/mL

  • Precision: Intra-assay CV < 10%; inter-assay CV < 10%

  • Sample Types: Culture supernatant, urine, serum, plasma (EDTA, sodium citrate and heparin)

  • Total Assay Time: 3 hours

  • Sample Size: 50μL

  • Specificity: No significant cross-reaction with with human PF-4, GROα, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-6, IL-7, IL-10, IL-12, TNFα, IFNα, IFNγ, or GM-CSF

Assay range and other values listed above are for the pre-coated plate kit; see product documentation for values specific to the reagent kit and antibody-pair kit.

Includes:Complete Kits contain pre-coated antibody-plates, detection antibodies, buffers, diluents, standards, and substrates. The Reagent Kit (previously called a “Screening Set”) contains matched antibodies, standard and detection reagents but no coated plates. The Antibody Pair Kit (previously called a “MiniKit”) contains only matched antibodies and standard (no plates or detection reagents).

TRUSTED_SUSTAINABILITY

Tekniske data

Analyseområde 25.6 to 1000pg/mL
Assay følsomhed <2pg/mL
Oversigt Human IL-8 ELISA Kit
Immunoassay-kitformat Colorimetric ELISA (TMB substrate) with Plates
Prøvetype Cellekultursupernatant, plasma (EDTA, citrat, heparin), serum, urin, Plasma (EDTA, Citrate, Heparin), Serum, Urine
Specificitet No significant cross-reaction with with human PF-4, GROa, IL-1a, IL-1ß, IL-2, IL-3, IL-4, IL-6, IL-7, IL-10, IL-12, TNFa, IFNa, IFNg, or GM-CSF
Tilstrækkelig til 96 mikropladebrønde
Sættets indhold Streptavidin-HRP Concentrate, 75 μL, TMB Substrate Solution, 13mL, Stop Solution, 13mL, Standard Diluent, 25mL, 30X Wash Buffer, 50mL, Lyophilized Recombinant Human IL-8 Standard, 2 vials, Adhesive Plate Covers, 6 ea, Anti-Human IL-8 Precoated 96-well Strip Plate, 1 ea, Biotinylated Antibody Reagent, 8mL, HRP Dilution Buffer, 14mL
Måling Absorbance at 450nm minus absorbance at 550nm
Præcision Intra-assay CV <10%; inter-assay CV <10%
Mængde 1 pladesæt
Prøvevolumen 50 μL
Mål Natural and recombinant human interleukin-8 (IL-8) and has been shown to recognize IL-8 derived from stimulated human umbilical vein endothelial cells
Samlet analysetid 3 hr.
Vis mere Vis mindre
Korrektion af produktindhold

Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

Produkttitel

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.

Mange tak! Din feedback er blevet sendt. Hos Fisher Scientific arbejder vi altid på at forbedre vores indhold for dig. Vi sætter pris på din feedback.