Thermo Scientific™ Finnpipette™ F1 Variable Volume Single-Channel Pipettes

Artikelnummer. p-4530195
Klik for at se tilgængelige muligheder
Volumen (metrisk):
0.2 to 2 μL
0.5 to 5 μL
0.5 to 5 mL
1 to 10 μL
1 to 10 mL
10 to 100 μL
100 to 1000 μL
2 to 20 μL
20 to 200 μL
30 to 300 μL
5 to 50 μL
Farve:
Blue
Green
Orange
Pink
Red
Turquoise
Yellow
Pakningsstørrelse:
Hver
Denne vare kan ikke returneres. Se returpolicy

Artikelnummer. 11827391

Brand: Thermo Scientific™ 4641010

Denne vare kan ikke returneres. Se returpolicy

Simplify volume adjustment with an easy set and forget lock mechanism, one of several convenient features of this ergonomic pipette.

Simplify volume adjustment with Thermo Scientific™ Finnpipette™ F1 Variable-Volume Pipettes, which include an easy set and forget lock mechanism that features an adjustable finger rest and proprietary soft touch tip ejection. An antimicrobial treatment protects the instrument against contamination.

Features:
  • Silver (Ag) ions create an antimicrobial surface that inhibits growth of bacteria, microbes, and fungus
  • “Set-and-forget” pipetting button enables easy volume adjustment
  • Pipetting button rotates freely when not in locking position
  • Finger rest can be adjusted 120° for optimal pipetting position
  • Light, smooth pipetting action enables better results over longer periods
  • Super blow-out piston with volumes of 50μL and below ensures delivery of micro-size drops
  • Proprietary soft-touch tip ejection minimizes forces needed for tip ejection
TRUSTED_SUSTAINABILITY

Tekniske data

Nøjagtighed ±12 to 2.5%
Kompatible tips Finntip Flex 10, 10, 50
Oversigt F1 Adjustable-Volume Pipetter
Farve Pink
Til brug med FinnTip™: Flex 10, 10, 50
Model- F1
Antal kanaler 1
Produktlinje Finnpipette™ F1
Type Variable Volume Pipette
Volumen (metrisk) 0.2 to 2 μL
Inkrementer 0.002 μL
Præcision 10 to 2%
Vis mere Vis mindre

Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Korrektion af produktindhold

Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

Produkttitel

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.

Mange tak! Din feedback er blevet sendt. Hos Fisher Scientific arbejder vi altid på at forbedre vores indhold for dig. Vi sætter pris på din feedback.