Tekniske data

Analyseområde 4.7 pg/mL
Assay følsomhed 4.69-300 pg/mL
Assay Sandwich ELISA
Konjugeret HRP
Produkttype Antibody Pairs
Specificitet This solid phase sandwich ELISA utilizes a monoclonal antibody specific for Human Cystatin SA.
Målarter Human
Til brug med (applikation) Sandwich ELISA
Gene Alias cystatin 2, cystatin S5, cystatin SA, Cystatin-2, Cystatin-S5, cystatin-SA, cysteine-proteinase inhibitor, MGC71924, salivary cysteine (thiol) protease inhibitor
Gen-id (Entrez) 1470
Gen symbol CST2
Værtsarter Rabbit
Sættets indhold
  • Detection Antibody: 0.25 mg/mL rabbit anti-Cystatin SA monoclonal antibody conjugated to horseradish-peroxidase (HRP) (in PBS, 50 % glycerol, pH 7.4).
  • Capture Antibody: 1.0 mg/mL of rabbit anti-Cystatin SA monoclonal antibody (in PBS, pH 7.4).
  • Standard: Each vial contains 15 ng of recombinant Cystatin SA.
  • Mængde 15 tallerkener
    Regulatorisk status RUO
    Opbevaringskrav Storage is content dependent.
    Mål Cystatin SA
    Teknik 1. Capture Antibody: Dilute to a working concentration of 2 μg/mL in CBS before coating. 2. Detection Antibody: Dilute to working concentration of 0.5 μg/mL in detection antibody dilution buffer before use. 3. Standard: Reconstitute with 1 ml detection antibody dilution buffer. After reconstitution, store at -20 to -80°C in a manual defrost freezer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 0.3 ng/mL is recommended.
    Vis mere Vis mindre
    Korrektion af produktindhold

    Dit input er vigtigt for os. Udfyld denne formular for at give feedback relateret til indholdet på dette produkt.

    Produkttitel

    Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.