Cytiva Whatman™ Lens Cleaning Tissue
Provides scratch-free cleaning solutions. Whatman™ Lens Cleaning Tissue safely removes surface moisture and grease.
| Description | Won't damage lenses or optical surfaces, leaves no fibers |
|---|---|
| Product Type | Lens Wipe |
| For Use With (Application) | Safe removal of surface moisture and grease. |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Cytiva Whatman™ Benchkote Surface Protector Sheets
Minimize mess and contamination during spills. Whatman™ Benchkote material has a high-quality, smooth, absorbent lab paper layer that soaks up liquid spills. A second laminated polyethylene layer prevents flow-through to the working surface.
| Length (Metric) | 460 mm |
|---|---|
| Product Type | Surface Protector |
| Material | Polyethylene |
| Width (Metric) | 570 mm |
| Dimensions (L x W) | 460 x 570mm |
| Content And Storage | 15° to 30°C |
|---|---|
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | Phosphate Buffered Saline (PBS) |
| Form | Liquid |
| Without Additives | No Calcium,No Magnesium,No Phenol Red |
| Endotoxin Level | =1.0EU/mL |
| pH | 7.0 to 7.2 |
| Certifications/Compliance | cGMP and ISO 9001:2000 Guidelines |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Cytiva HyClone™ Dulbecco's Modified Eagles Medium
Designed to support cell culture growth and biomanufacturing processes.
| Content And Storage | 2° to 8°C, away from light |
|---|---|
| Sterilization Method | 0.1 μm Sterile-filtered |
| Form | Liquid |
| Certifications/Compliance | ISO 9001:2000 |
Cytiva Polypropylene Screw Lid GL45 Kit
Used to secure containers. Cytiva Polypropylene Screw lid GL45 Kit comes with screw lid and cap membrane.
| Thickness (Metric) | 435 μm |
|---|---|
| Flow Rate | 47 sec./100mL |
| Particle Retention | 1.5 μm |
| Type | RTU Filter for Total Suspended Solids Analysis |
| Temperature (English) Max. | 1022°F |
| Description | Our Whatman glass microfiber filter papers in grade 934-AH RTU have been pre-washed, dried (or ignited), cooled, desiccated and weighed, which eliminates the pre-treating steps that are otherwise required by the US EPA Laboratory Standard Method 2540 part |
| Thickness (English) | 0.017 in. |
| Temperature (Metric) Max | 550°C |
| Quantity | 100 pieces |
| Grade | 934-AH RTU |
| Material | Borosilicate Glass |
| For Use With (Application) | Monitoring of rivers, lakes and coastal waters |
| Waterflow Rate | 341 mL/min |
Cytiva HyClone™ RPMI 1640 Media
Designed to support cell culture growth and biomanufacturing processes.
| Content And Storage | 2° to 8°C, away from light |
|---|---|
| Sterilization Method | 0.1 μm Sterile-filtered |
| Product Type | RPMI 1640 |
| Form | Liquid |
| Certifications/Compliance | ISO 9001:2000 |
Cytiva Whatman™ 30mm Puradisc PTFE Syringe Filters
Designed to be resistant to organic solvents. Whatman™ 30mm Puradisc PTFE Syringe Filters are ideal for the clarification of aggressive organic solvents and can also be used as a venting filter for small vessels.
| Type | Syringe Filter |
|---|---|
| Outlet Style | Male Luer |
| Diameter (Metric) | 30 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Polypropylene (PP) |
| Material | PTFE |
Cytiva Pharmalyte™ Carrier Ampholytes
Use in Isoelectric focusing. Cytiva Pharmalyte™ Carrier Ampholytes prepared by the co-polymerization of glycine, glycylglycine, amines, and epichlorohydrin, are available in five broad-range and four narrow-range pH intervals.
| Form | Liquid |
|---|---|
| Product Type | Pharmalyte carrier Ampholyte |
| For Use With (Equipment) | PhastSystem Automated Electrophoresis Unit |
| Formulation | Co-polymerization of Glycine, Glycylglycine, Amines and Epichlorohydrin |
| Color | Colorless to Light Yellow |
| Quantity | 25mL |
| Storage Requirements | 2° to 8°C |
| For Use With (Application) | IEF |
anti-Rabbit IgG, peroxidase-linked species-specific whole antibody (from donkey) Secondary Antibody, Cytiva
A highly species-specific anti-Rabbit IgG. Cytiva Lifescience™ anti-Rabbit IgG, peroxidase-linked species-specific whole antibody (from donkey) Secondary Antibody is used with Amersham™ ECL Western Blotting detection reagents.
| Antigen | IgG |
|---|---|
| Purification Method | Affinity Purified |
| Host Species | Donkey |
| Conjugate | HRP |
| Classification | Monoclonal |
| Isotype | IgG |
| Primary or Secondary | Secondary |
Cytiva Fetal Bovine Serum, Heat Inactivated
GE Hyclone Fetal Bovine Serum, Heat Inactivated, is sourced from South America and complies with the EU regulations.
Cytiva GFX™ PCR DNA and Gel Band Purification Kit
Purify and concentrate PCR products or DNA fragments ranging in size from 50 bp to 10 kb. Cytiva Life Sciences™ illustra™ GFX™ PCR DNA and Gel Band Purification Kit can be used to purify DNA from reaction volumes up to 100μL or agarose gel slices of up to 900mg.
| Includes | GFX™ columns, collection tubes, color-coded bottles of capture Buffer, Wash Buffer, two Elution Buffers |
|---|---|
| Description | Designed for the rapid purification and concentration of PCR products or DNA fragments ranging in size from 50 bp to 10 kb. This kit can be used to purify DNA from reaction volumes up to 100 μl or agarose gel slices up to 900 mg. |
| Product Type | illustra GFX PCR DNA and Gel Band Purification Kit |
| Formulation | Tris HCl and sterile Water |
| Sample Type | Agarose Gel Slices,DNA Solutions,Enzyme Reactions,PCR Mixtures |
| Sample Volume | 50 bp-10 kb |
| Yield | PCR 10 μl elution volume-65%, PCR 50 μl elution volume-82%, 300 mg agarose 10 μl elution volume-57%, 300 mg agarose 50 μl elution volume-91% |